Food grade lobe pump is one of the products specially developed by ACCUVON pumps company to meet the customers in the production process of high hygiene requirements. Working chamber has sanitary rotor, rotor locking nut O - ring, pump body without sanitary dead angle and Higher hygienic grade. Support CIP, SIP. The surface roughness is 0.2--0.6mm, in accordance with 3A, FDA standards. Can be widely used food, medicine and other materials with high requirements for hygiene level.
Specifications:
ACCUVON | rate of flow l/rev | flow (m³/h) | pressure (Mpa) | speed rpm | Flange diameter DN mm | power Kw |
AC25 | 0.196 | 0.1-7 | 0-1.2 | 10-600 | DN25 | 0.75-5.5 |
AC50 | 0.392 | 0.2-14 | 0-1.0 | 10-600 | DN50 | 1.1-5.5 |
AC75 | 0.588 | 0.3-21 | 0-0.6 | 10-600 | DN50 | 1.1-5.5 |
AP80 | 1.125 | 0.6-400 | 0-1.8 | 10-600 | DN80 | 3-22 |
AP100 | 1.875 | 1.1-66 | 0-1.4 | 10-600 | DN100 | 3-22 |
AP120 | 2.864 | 1.7-103 | 0-1.0 | 10-600 | DN100 | 3-22 |
AP140 | 3.714 | 2.2-133 | 0-0.6 | 10-600 | DN125 | 7.5-22 |
AF125 | 4.566 | 2.7-164 | 0-1.6 | 10-600 | DN125 | 11-55 |
AF150 | 6.828 | 4-246 | 0-1.2 | 10-600 | DN150 | 11-55 |
AF200 | 9.456 | 5.5-340 | 0-0.8 | 10-600 | DN200 | 11-55 |
AX250 | 12.5 | 7.5-487 | 0-2.5 | 10-650 | DN250 | 22-315 |
AX300 | 25 | 15-975 | 0-1.0 | 10-650 | DN300 | 30-315 |
AX350 | 37.5 | 22.5-1463 | 0-0.6 | 10-650 | DN350 | 45-315 |
AX450 | 50 | 30-1950 | 0-0.4 | 10-650 | DN450 | 55-315 |
AX350D | 75 | 45-2926 | 0-0.6 | 10-650 | DN350*2 | 90-450 |
AX450D | 100 | 60-3900 | 0-0.4 | 10-650 | DN450*2 | 110-600 |
Note: Above flange is regular for each model, besides we also offer various flange connection according to your requirements
1. Tested medium in the table: water.
2. Speed, flow rate, electrical power and pressure will be according to different liquid properties.
3. Port size can be changed as needed.
4. ACCUVON reserves the right to change specifications without prior notification.
Solution guidance
Problem | Possible Cause | Remedy |
Motor Operational but No Fluid Delivery | Direction of Rotation | Check direction of rotation is in line with arrow on casing and nameplate |
Air pocket in suction line | Ensure suction line filled with fluid, pipework slopes upwards, no kinks in suction line and pipework is as straight as possible. | |
Relief Valve Failure | Clean Relief Valve. Check pressure setting. Recalibrate | |
Check Valve Jammed | Clean check valve. Check operation | |
Air Ingress through Seal | Check seals for air ingress, all pipework, and connected gaskets. Check pump O Rings. Replace pump seal if necessary. | |
Insufficient Capacity | Relief Valve Opening or Jammed | Check relief valve settings. Recalibrate. Check and clean as a plug may have formed or solid entered jamming open. |
Air Ingress | Check seals for air ingress, all pipework, and connected gaskets. Check pump O Rings. Replace pump seal if necessary. | |
Low NPSH | Shorten and enlarge suction line diameter. Deepen suction pipe, increase tank contents, reduce pump speed and check fluid viscosity against pump design | |
Pump Worn | Check internal lobe spacing. Replace lobes | |
Check Valve Jammed | Clean check valve. Check operation | |
Pump Noisy | Pump Cavitating | Increase pipework diameter. Reduce suction head. Check fluid viscosity. Clean filters. Reduce pump speed. Increase fluid level in tank. |
Lobe / Rotor Damage | Check lobes and replace if necessary | |
Misalignment | Realign Pump. Check coupling and rubber | |
Vibration in safety valve | Increase pressure setting or replace |