
Add to Cart
Chemical Fiber Lobe Pump With Acid-Resistant Stainless Steel Protect Plate
Working Principle
Lobe pump is self-priming, valveless positive displacement pump. Through the two parallel shafts in the synchronous gear to driven the rotor synchronous operation, chamber form a vacuum between the rotor vanes and casting surrounding, so that the medium was inhaled, then displaced through the discharge-side. Pump operating direction can be reversed by changing the direction of rotor rotation, to be a two-way pump for reversing operation.
Specifications:
Description | Rotary Lobe Pumps |
Rotor | tri-lobe SS 316 |
Seal | Electric sealing sensor / Double-acting mechanical seal |
Axial and radial casing protection | Wear-resistant steel / Hardened steel / Stainless steel / SIC |
Drive | Variable geared motor / Combustion motor / Hydraulic motor |
Pump | Full of stainless steel |
Gear | Helical geared motor / Manual adjustable speed motor |
Speed | 10 - 600 rpm |
Custom printing | Acceptable |
Parameter of AP 80
Drive | Weight | Dimensions | |
KW | KG | L / mm | H / mm |
3 | 190 | 1158 | 394 |
4 | 202 | 1178 | 419 |
5.5 | 223 | 1258 | 454 |
7.5 | 236 | 1298 | 454 |
11 | 291 | 1380 | 509 |
15 | 354 | 1425 | 509 |
Design 1 | Short, s traight pipe connectors with connection flange and gasket, in mm / inches approx.
AP 80 | DN 50 mm | DN 65 mm | DN 80 mm | DN 100 mm | DN 125 mm |
Solution guidance
Problem | Possible Cause | Remedy |
Motor Operational but No Fluid Delivery | Direction of Rotation | Check direction of rotation is in line with arrow on casing and nameplate |
Air pocket in suction line | Ensure suction line filled with fluid, pipework slopes upwards, no kinks in suction line and pipework is as straight as possible. | |
Relief Valve Failure | Clean Relief Valve. Check pressure setting. Recalibrate | |
Check Valve Jammed | Clean check valve. Check operation | |
Air Ingress through Seal | Check seals for air ingress, all pipework, and connected gaskets. Check pump O Rings. Replace pump seal if necessary. | |
Insufficient Capacity | Relief Valve Opening or Jammed | Check relief valve settings. Recalibrate. Check and clean as a plug may have formed or solid entered jamming open. |
Air Ingress | Check seals for air ingress, all pipework, and connected gaskets. Check pump O Rings. Replace pump seal if necessary. | |
Low NPSH | Shorten and enlarge suction line diameter. Deepen suction pipe, increase tank contents, reduce pump speed and check fluid viscosity against pump design | |
Pump Worn | Check internal lobe spacing. Replace lobes | |
Check Valve Jammed | Clean check valve. Check operation | |
Pump Noisy | Pump Cavitating | Increase pipework diameter. Reduce suction head. Check fluid viscosity. Clean filters. Reduce pump speed. Increase fluid level in tank. |
Lobe / Rotor Damage | Check lobes and replace if necessary | |
Misalignment | Realign Pump. Check coupling and rubber | |
Vibration in safety valve | Increase pressure setting or replace |
Advantage
• Low shear/Pulse free operation
• Excellent for oil/water and high viscosity liquid.
• Ability to pump at constant pressure at different flow rates
• Self-priming to 9.5 meters
• Forward and reverse pumping operation
• Space-saving compact design
• 10 to 1 turn down capability and reverse capability
• Run dry ability for a period of time
Quality inspection photos